Use a QC5 DLN advanced dry coating thickness gauge to measure coatings and platings applied on Non-Ferrous bases and to transfer data stored in the unit memory to a PC using DMQ DataCenter software.
QC5 models feature 9 calibration modes, calibration memories, a continuous measurement mode, statistics, graphics and much more.
Modes: Magnetic induction Range: 0 to 15mm / 0 to 5.905in *Depending on probe and material Resolution: Up to 99.9µm, 0.1µm or up to 4.99Mil, 0.01Mil Above 100µm, 1µm or above 5Mil, 0.1Mil Precision: ±1 at 3% +2μm (+0.07Mil) *Depending on probe Measuring Velocity: Approximately 99 measurements per minute
9 modes: Base & 1 point Base & 2 point Muiltipoint 1 point Base ISO (ISO 19840) SSPC (SSPC-PA2) SWE (SS 184160) AUS (AS 3894.3) Set Number of Samples User defined except for specific calibration modes Memory Save commonly used shim values
Type of Base Permanent indicator Counter Configuration Measure number of layers in a coating Histogram Range User defined high and low values Measurement Modes Continuous and Hold Last Differential Mode: Difference between actual measurement and reference value Internal Clock: Date and Time (Selectable format)
Types: Minimum, maximum, average, range, standard deviation, coefficient of variation Error: High, Low, High%, Low% based on high and low alarm settings Calculations are based on stored values only
Upgrade to a QC5 DLC with the purchase of a license and a combined probe
Low & High: User defined Alarm Types: Visible: flashing backlight or irregular digits Audible: intermitent beep
Digits: 17mm / 0.66in tall Graphic LCD: 128×64 pixels Viewable Area: 45 x 30mm / 1.77 x 1.18in Backlight: LED backlight (ON, OFF, Auto) Contrast: Digital 30 steps
Languages: English, Spanish, Portuguese Menu Screens: Icon based User ID: Personal information with password protection
Type: Non-Ferrous Probe Range: Non-Ferrous, 0 to 1500µm or 0.025 to 19.999in Resolution: Up to 99.9µm, 0.1µm or up to 4.99Mil, 0.01Mil Above 100µm, 1µm or above 5Mil, 0.1Mil Material Base: Non-Ferrous: Aluminum, Copper, Bronze, etc. Minimum Base Thickness: Non-Ferrous: 0.3mm or 0.01in Minimum Convex Radius: Non-Ferrous: 5mm or 0.19in Minimum Concave Radius: Non-Ferrous: 25mm or 0.98in Minimum Sample Diameter: 5mm or 0.19in
Metric: Microns (µm) Millimeters (mm) Imperial: Inches (Mil)
Storage: Up to 32000 readings Data Transfer: Send to a PC using dmq DataCenter software included at no additional charge Organization: 8 files with 10 character alphanumeric naming Capture Modes: Manual: Touch the “Store” key to store values Single: Automatic each time the probe is coupled Continuous: Automatic while the proble is coupled Date and Time Register: Register day and time
Connectivity: USB (cable included) or RS232 (optional cable)
Touch-Sense Keypad: No mechanical parts Keypad: Sensitivity adjustment Auto pressure detection Auto scrolling detection
Dimensions: H: 117mm / 4.60in L: 78.74mm / 3.10in W: 24mm / 0.94in Weight: 200g / 7.05oz with batteries Working Temperature: -10°C to 50°C / 14°F to 122°F Storage Temperature: -20°C to 60°C / -4°F to 140°F Enclosure: High impact ABS with rubber sides for easy grip Front Panel: Polycarbonate
Batteries: 2 x AA 1.5v Alkaline 2 x AA 1.2v Ni-MH Rechargeable Battery Life: 100 hours with backlight off Battery Indicator: On all screens with a low level alarm Auto-Off: Programmable 1 to 120 minutes
Electronic Unit: 5 year limited Probes: 6 months