image

QC2 F

The QC2 DLF is used to measure the thickness of dry non-conductive coatings applied over Ferrous bases. Coatings such as paint, varnish and laquer, or platings such as nickel, zinc and chrome, can all be maesured quickly and accurately with a stable built-in probe.

The gauge is just the right size to be robust and have a large LCD display with a bright LED backlight. It features 3 calibration modes, average reading, unit, coulping indicator and battery level indicator.


Product Download Bochures
QC2 F Quick Guide Download
QC2 F Datasheet Download

Measuring

Method:
Eddy current
Probe:
Intregated
Range:

0 to 1250μm / 0 to 49mils
Resolution:
Hasta 99.9µm: 0.5µmm.
         9.99Mil: 0.01Mil.
Desde 100µm: 1µm.
          10Mil: 0.1Mil.
Precision:
±1 at 3% +2μm (+0.07Mil)

Units

Metric:
Microns (µm)
Imperial:
Inches (Mils)

Calibration

Modes:
Base only
Base and one point

Features

Coupling:
Coupling indicator

Alarms

Low & High:
User defined value
Alarm Types:
Visible: Flashing backlight or irregular digits

Display

Digits:
17mm / 0.66in tall
Graphic LCD:

128×64 pixels
Viewable Area:
45 x 30mm / 1.77 x 1.18in
Backlight:
LED backlight (ON, OFF, Auto)

User Interface

Languages:
English o Spanish

User Interface

Languages:
English, Spanish

Front Panel

Membrane keyboard
High strength polyester

Electronic Unit

Dimensions:
H: 115mm / 4.52in
L: 69mm / 2.7in
W: 28mm / 1.10in
Weight:
175g / 7.05oz with batteries
Working Temperature:
-10°C to 50°C / 14°F to 122°F
Storage Temperature:
-20°C to 60°C / -4°F to 140°F
Enclosure:
High impact ABS
Front Panel:
Polyester

Power Supply

Batteries:
2 x AA 1.5v Alkaline
2 x AA 1.2v Ni-MH Rechargeable
Battery Life:
100 hours with backlight off
Battery Indicator:
On all screens with a low level alarm
Auto-Off:
3 minutes

Warranty

Electronic Unit:
5 year limited